Bandhan CPVC Pipes & Fittings

Bandhan CPVC Pipes and Plumbing

Used for hot and cold water applications

Bandhan CPVC Pipes & Fittings

Bandhan CPVC Plumbing System is ideal for Hot and Cold Water Plumbing Applications. Manufactured using the best quality raw material from globally reputed manufacturers. Bandhan CPVC Pipes and Fittings are designed for an everlasting performance. Our in-house compounding technology and state of art manufacturing unit ensure total control from raw material to finished product ensuring a very high product consistency Bandhan CVPC plumbing system is currently available in a range of ½” to 2” with pipes as per IS – 15778 in SDR 11 & 13.5 and fittings as per ASTM D – 2846 in SDR 11.”

FIELDS OF APPLICATION

RESIDENCE

COMMERCIAL COMPLEX

SWIMMING POOLS

EDUCATIONAL INSTITUTES

HOSPITALS

industrial cpvc pipes

INDUSTRIES

RESIDENCE
ISI logo

FEATURES AND BENEFITS

  • Safe for drinking water
  • Does not support combustion
  • UV Resistance
  • High pressure and temperature bearing capacity
  • Lower thermal conductivity

Bandhan CPVC Plumbing System

Used for hot and cold water applications

CPVC plumbing system

Bandhan CPVC pipes and fittings is ideal for Hot and Cold Water Plumbing Applications. Manufactured using the best quality raw material from globally reputed manufacturers. Bandhan CPVC Pipes and Fittings are designed for an everlasting performance. Our in-house compounding technology and state of art manufacturing unit ensure total control from raw material to finished product ensuring a very high product consistency.

Bandhan CVPC plumbing system is currently available in a range of ½” to 2” with pipes as per
IS – 15778 in SDR 11 & 13.5 and fittings as per ASTM D – 2846 in SDR 11.

FIELDS OF APPLICATION

Residence

Commercial
Complex

Swimming Pools

Educational Institures

Hospitals

industrial cpvc pipes

Industries

RESIDENCE
ISI logo
Bandhan CPVC Pipes & Fittings

FEATURES AND BENEFITS

Strong and durable

UV resistant

UV resistant

Low thermal conductivity

Temperature

Withstands temperature up to 93˚C

lead free - safe for water distribution

Lead Free - safe for water distribution

Hot and cold water compatible

Hot and cold water compatible

PRODUCT Details

Click on the image for more information

Click on the image for more information

FAQs

Bandhan CPVC plumbing system can be used in residential and commercial establishments, hotel and resorts, hospitals, high-rise and low-rise buildings, corporate offices, swimming pools, academic institutes, manufacturing plants etc.

Currently, Bandhan CPVC Pipes are available in a range of ½” to 2” with pipes as per IS – 15778 in SDR 11 & SDR 13.5 and fittings as per ASTM D – 2846 in SDR 11.

 

Bandhan CPVC water pipe is ideal for hot and cold-water plumbing applications.

Bandhan CPVC plumbing system can withstand temperatures up to 93°C.

Bandhan CPVC pipes are UV stabilized in the manufacturing process itself and hence can be used for all the external plumbing applications.

FAQs

Bandhan CPVC plumbing system can be used in residential and commercial establishments, hotel and resorts, hospitals, high-rise and low-rise buildings, corporate offices, swimming pools, academic institutes, manufacturing plants etc.

Currently, Bandhan CPVC Pipes are available in a range of ½” to 2” with pipes as per IS – 15778 in SDR 11 & SDR 13.5 and fittings as per ASTM D – 2846 in SDR 11.

 

Bandhan CPVC plumbing system is ideal for hot and cold-water plumbing applications.

Bandhan CPVC plumbing system can withstand temperatures up to 93°C.

Bandhan CPVC pipes are UV stabilized in the manufacturing process itself and hence can be used for all the external plumbing applications.

Technical details

PRESSURE DERATING FACTORS AT WORKING TEMPERATURES:

Working Temperatures
°F(Fahrenheit) °C(Celsius) Derating factors of Bandhan Pipes
73-80 23-27 1.00
90 32 0.91
100 38 0.82
120 49 0.65
140 60 0.50
160 71 0.40
180 82 0.25

INITIAL SET SCHEDULE AVERAGE FOR Bandhan CPVC SOLVENT CEMENT:

Set Schedule is the necessary time to be allowed before the joint can be handled. (In damp or humid weather allow 50% or more set time.)

Temperature Range
(Temperature range during assembly and setting duration)
½” to 1¼”1½” to 2”
16°C to 38°C2 minutes5 minutes
5°C to 16°5 minutes10 minutes
-18°C to 5°C10 minutes15 minutes

AVERAGE JOINT CURE SCHEDULE FOR Bandhan CPVC SOLVENT CEMENT:

The joint cure schedule is the necessary time to be allowed before pressurizing the system. (Allow 50% more set time in damp or humid weather)

Temperature Range

(Temperature range during assembly and setting duration)

½” to 1¼”1½” to 2”
Up to 11 Kg/cm211 to 22 Kg/cm2Up to 11 Kg/cm211 to 22 Kg/cm2
16°C to 38°C15 minutes6 hours30 minutes12 hours
5°C to 16°20 minutes12 hours45 minutes24 hours
-18°C to 5°C30 minutes48 hours1 hour96 hours

THERMAL EXPANSION & CONTRACTION:

The stress developed in CPVC pipes is generally much lesser than developed in a metal pipe for the same temperature, primarily because of the difference in elastic modulus.

CPVC expands when heated and contracts when cooled, like all piping material. CPVC, regardless of the pipe diameter will expand around 25mm per 15m length (1 inch per 50 feet) in length. Necessary provisions should be made to accommodate when it is put into a 23°C temperature increase. Laboratory testing and installation experience have also demonstrated that the practical issues are much smaller than the coefficient of thermal expansion would suggest.

Thermal Expansion is mainly a concern in hot water lines. A long straight run may require an offset or loop. Only one expansion loop, properly sized is required in a single straight run, regardless of its total length. If more convenient, two or more smaller expansion loops, properly sized, can be utilised in a single run of the pipe to accommodate the thermal movement. Also, make sure to hang the pipe with smooth straps that will not restrict the same.

Thermal Expansion Formula:

∆ L = LP C ∆T

Where in,
∆L = Change in length due to change in temperature (in.), Lp = Length of pipe (in.)
C = Coefficient of Thermal Expansion (in./in./ °F) = 3.4 x 10⁻⁵ in./in./ °F for

CPVC Expansion Loop Formula:

L =

Where in,

L = Loop in Length (in.), E = Modulus of Elasticity at maximum temperature (psi),
S = Working Stress at Maximum Temperature (psi), D = Outside Diameter of pipe (in.),
∆L = Change in length due to change in temperature (in.).

PRECAUTIONS:

  • The Brush should be clean and dry before commencing the solvent welding process.
  • When the system is to be concealed, it should be pressure tested before the concealment.
  • Do not attempt cementing in the rain or in the presence of moisture.
  • The cement should be used within the expiry period mentioned on the container.
  • Keep cement away from all the sources of ignition, heat, sparks and open flame.
  • Close the cement container tightly after use.
  • Store the solvent cement and piping components in a cool area.

ADDITIONAL INFORMATION

  • Use pipes, fittings and solvent cements manufactured by Bandhan Pipes for optimum results.
  • Installation process should be carried as per instructions and safe practices must be followed.
  • Clean the pipe and fittings with a clean dry cloth to remove any dirt.
  • Cut the pipe as square or perpendicular as possible before making a joint.
  • Ensure no sharp edges are in contact with the fittings surface while inserting the pipe.
  • Ensure proper alignment of pipe and fittings to avoid stress on the joints.
  • Ensure installation is done in such a way that there are no chances of air entrapment.
  • Always conduct hydraulic pressure testing after installation to detect any leaks and faults.
  • Wait for the appropriate cure time before pressure testing. Fill lines slowly and allow air to escape from the system prior to pressure testing.
  • Paint pipes exposed to sunlight with a water-based paint.
  • Provide additional support to the brass side of CPVC/brass transition or other for keeping any heavy object to support the weight of the metal system.